Description
The PRO-XR1 is a unique set of spiral wound membranes customized specifically for industrial process applications. This membrane is based on existing Hydranautics high performance membrane products which have been specially designed to treat a variety of challenging industrial feed streams including high fouling or having special ion concentration requirements.
Specified Performance
| Permeate Flow (Nominal) | 11,500 gpd (43.5 m3 /d) |
| Salt Rejection: | 99.8% (99.5% minimum) |
| Test Conditions: | 2,000 ppm NaCl solution 225 psig (1.55 MPa) Applied Pressure 77°F (25°C) Operating Temperature 15% Permeate Recovery 6.5 - 7.0 pH Range |
The Specified Performance is based on data taken after a minimum 10 minutes of operation. Actual testing of elements may be done at conditions which vary from these exact values; in which case, the performance is normalized back to these standard conditions. Permeate flow for individual elements may vary ±15 percent from the value specified.