AQUALINK TETRA SERIES SEAWATER REVERSE osmosis SYSTEMS
100 m3/day to 1500 m3/day
Membrane filtration process for obtaining pure water, which is applied to waters where conventional treatment systems are insufficient (sea water, well water with high conductivity, etc.), separating all unwanted minerals in the water from the water, is called Reverse Osmosis.
STANDARD FEATURES
Membrane sleeves FRP
TFC Spiral Wound Membranes 8" diameter
AISI304 or AISI316 Dublex quality stainless steel high pressure pump
St37 Epoxy painted Carbon Steel or AISI304 Stainless Steel chassis
Cartridge filtration with 5 micron precision
Low pressure line U-PVC PN16
High pressure line AISI316Ti or Duplex Stainless Steel
Introduction Electric actuated butterfly valve
Low and High pressure switch
Clean and Waste water flow meters
Glycerin manometers
Product water conductivity indicator (0-2000µS/cm)
Inlet and Product Water pH Meter (optional)
On-Off switch
Alarm and Status lamps
380V/50Hz/3ph
IP56 control board
Recommended Intake Water Limits
Inlet water TDS : 38,000 - 41,000 ppm
Working pressure: Between 50 and 70 bar
Inlet water pressure: 2 to 5 bar
Inlet water pH range: 6 – 8
Silica (SiO2) Tolerance 25 ppm max. 60% yield
Max. Inlet water temperature = 30º C Max.
Max Iron (Fe) tolerance 0.05 ppm, if any Antiscalant dosage 0.2 ppm
It should not be Hydrogen Sulfide.
There should be no blur. (NTU)